{"created":"2023-06-19T10:34:53.005184+00:00","id":757,"links":{},"metadata":{"_buckets":{"deposit":"ea4e97cc-732f-4c6a-bb3b-728097683963"},"_deposit":{"created_by":14,"id":"757","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"757"},"status":"published"},"_oai":{"id":"oai:ous.repo.nii.ac.jp:00000757","sets":["296:314:320"]},"author_link":["9752"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1987-03-05","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"203","bibliographicPageStart":"187","bibliographicVolumeNumber":"22","bibliographic_titles":[{"bibliographic_title":"岡山理科大学紀要. A, 自然科学","bibliographic_titleLang":"ja"},{"bibliographic_title":"Bulletin of Okayama University of Science. A, Natural Sciences","bibliographic_titleLang":"en"}]}]},"item_1_creator_6":{"attribute_name":"著者名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"高橋, 信介","creatorNameLang":"ja"},{"creatorName":"タカハシ, ノブスケ","creatorNameLang":"ja-Kana"},{"creatorName":"Takahashi, Nobusuke","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_11":{"attribute_name":"抄録(日)","attribute_value_mlt":[{"subitem_description":"核研ES-Beam(γ2-Line)のIntensityの絶対値測定を行った。TL-Sheetに照射したES-Beamは, Energy 600(MeV), 照射量およそ9×10^4(electrons/10sec)から3×10^9(electrons/10sec)までの7段階である。TL-Sheetの読みだしは, TL Photon Counting SystemとTL-SDR System(熱ルミネッセンス2次元読取りシステム)で行った。TL-SDR SystemによりTL-SheetからもES-BeamのProfileを知ることができた。","subitem_description_language":"ja","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"The absolute intensity of Electron-Synchrotron BEAM has been measured by thermoluminescence [TL]-Sheets at Institute for Nuclear Study. The beam energy was about 600 (MeV) and the beam intensity range from 9×10^4 (electrons/10 sec) to 3×10^9 (electrons/10 sec). The TL-Sheets and X-ray films were irradiated with the electron beam. The TL-Sheets were analyzed by using the TL Photon Counting System and the TL Spatial Distribution Read-out System. By using the latter system which realized to make the two dimensional electron density map, the beam profile was measured quantitatively at all ranges without saturation for the case of the TL-Sheets, while for the case of X-ray films with saturation (beam intensity>1.2×10^7 electrons).","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00033244","subitem_source_identifier_type":"NCID"}]},"item_1_text_10":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Graduate School of Science, Okayama University of Science"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_language":"ja","subitem_text_value":"岡山理科大学大学院理学研究科"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"1987-03-05"}],"displaytype":"detail","filename":"KJ00000063310.pdf","filesize":[{"value":"745.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"url":"https://ous.repo.nii.ac.jp/record/757/files/KJ00000063310.pdf"},"version_id":"9f44b081-4f4e-4a08-b27d-7c7c38485022"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"TL-SHEET による ES-BEAM の INTENSITY の測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"TL-SHEET による ES-BEAM の INTENSITY の測定","subitem_title_language":"ja"},{"subitem_title":"Measurment of ES-BEAM Intensity by TL-SHEET","subitem_title_language":"en"},{"subitem_title":"TL SHEET ニヨル ES BEAM ノ INTENSITY ノ ソクテイ","subitem_title_language":"ja-Kana"}]},"item_type_id":"1","owner":"14","path":["320"],"pubdate":{"attribute_name":"PubDate","attribute_value":"1987-03-05"},"publish_date":"1987-03-05","publish_status":"0","recid":"757","relation_version_is_last":true,"title":["TL-SHEET による ES-BEAM の INTENSITY の測定"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2023-09-27T05:40:32.773016+00:00"}