WEKO3
アイテム
純流体素子による圧力のオンオフ制御について
https://ous.repo.nii.ac.jp/records/436
https://ous.repo.nii.ac.jp/records/436ddb67fae-4e3d-4e82-b3cf-12d36ea56a13
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(1) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 1972-12-25 | |||||||||||||||||
タイトル | ||||||||||||||||||
タイトル | 純流体素子による圧力のオンオフ制御について | |||||||||||||||||
言語 | ja | |||||||||||||||||
タイトル | ||||||||||||||||||
タイトル | On the On-off Control of Pressure with Fluidic Elements | |||||||||||||||||
言語 | en | |||||||||||||||||
タイトル | ||||||||||||||||||
タイトル | ジュンリュウタイ ソシ ニヨル アツリョク ノ オン オフ セイギョ ニツイテ | |||||||||||||||||
言語 | ja-Kana | |||||||||||||||||
言語 | ||||||||||||||||||
言語 | jpn | |||||||||||||||||
資源タイプ | ||||||||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||
資源タイプ | departmental bulletin paper | |||||||||||||||||
ページ属性 | ||||||||||||||||||
内容記述タイプ | Other | |||||||||||||||||
内容記述 | P(論文) | |||||||||||||||||
著者名 |
米澤, 洋
× 米澤, 洋
× 逢坂, 一正
|
|||||||||||||||||
著者所属(日) | ||||||||||||||||||
ja | ||||||||||||||||||
九州工業大学 | ||||||||||||||||||
著者所属(日) | ||||||||||||||||||
ja | ||||||||||||||||||
岡山理科大学機械理学科 | ||||||||||||||||||
抄録(英) | ||||||||||||||||||
内容記述タイプ | Other | |||||||||||||||||
内容記述 | In recent years, it has been reported a number of application of fluidics to industry. But there is few application to process control. This report deals with an on-off control of pressure in air tank by means of fluidics. The control system is constructed with an air tank, an on-off operation valve, needle valves, an orifice and one fluidic bistable element etc.. The characteristics of elements are examined, and the results is presented. As one of result, it was recognized that the plant consisting of capacitance and restsiction is not the first order element, and about this point a theoretical explanation is offered. This control system is very simple but sufficient results were obtained in respect to the response of system. But in this system, abjustment of supply pressure to a fluidic element is unavoidable in order to get good responses of system. This problem is the subject for a future study. | |||||||||||||||||
言語 | en | |||||||||||||||||
雑誌書誌ID | ||||||||||||||||||
収録物識別子タイプ | NCID | |||||||||||||||||
収録物識別子 | AN00033233 | |||||||||||||||||
書誌情報 |
ja : 岡山理科大学紀要 en : Bulletine of Okayama University of Science 巻 8, p. 139-147, 発行日 1972-12-25 |